biohazard waste disposal guidelines 1. The ground should be flat when install the incinerator. There should be 100cm at least between the incinerator  and the walls on the two sides and the back, which is in convenient maintenance and repair. 2.  A), Place the incinerator main body(combustion chamber) and fixed with bolts and Asbestos tape. B), Place the wet scrubber system and fixed with bolts and Asbestos tape. C). Install chimneys and fixed with bolts, Asbestos tape and Steel Rope. D). Fix the incineration house roof. E). Fix burner, blower, wind tube, electric system, fuel system. 3. Check the electric wire: the incinerator’s electric circuit should be linked with the ground wire to guard against current leakage.  The link-up of the electric wire should be checked carefully before starting the incinerator, in case of wrong link-up or leakage. 4. Check of the fuel supply system: Except the Burner’s soft pipe which is used for the fuel flowing-in and flowing-back, all the rest pipes must use brass or steel pipe. No leakage is allowed at pipe junctions. Any leakage should be blocked in time. 5. Install steel rope with the chimney, to avoid tilt by wind.  6. Install net cover at the blower, to avoid sundries. 7. If the fuel is Natural Gas with gas burner, please contact with local administration section and install gas supplier system. 8. Crane or forklift is necessary when download/upload/install incinerator.  9. Topped work house roof after installation. 10.Get the video material: http://www.eclover.net/category/incinerator-video/...
How medical waste is incinerated? The pyrolytic incinerator comprises a pyrolytic chamber and a post-combustion chamber. Medical waste is thermally decomposed in the pyrolytic chamber through  an oxygen-deficient, medium-temperature combustion process (800– 900°C), producing solid ashes and gases.   What are the treatment methods for treatment of bio medical waste? Thermal processes     Low-heat systems (operates between 93 -177oC) use steam, hot water, or electromagnetic radiation to heat and decontaminate the waste     High-heat systems employ combustion and high temperature plasma to decontaminate and destroy the waste. …     Incineration.     Autoclaving.     Microwaving.     Deep Burial.   Nanjing Clover Medical Technology...
TS10 PLC Waste Incinerator   Outline Dimension:1.75 x 1.3 x 1.7m Weight: Ave.1500kgs Main body(Primary combustion chamber) Material:Carbon Steel Q235B+Stainless Steel 310s+refractory firebrick material(high temperature resistance up to 1750℃) Capacity: 10-20kg/batch Combustion temperature: 800-1000℃ With chamber door, oxygen supplementation wind port, burner port, temperature control and alarm device, etc. [1 unit ] Secondary combustion chamber Material:Carbon Steel Q235B+Stainless Steel 310s+refractory firebrick material(high temperature resistance up to 1750℃) Combustion temperature:1000-1200℃ With observation port, burner port, temperature control and alarm device, etc. [1 unit ] High temperature flue gas filtration chamber Material: Outside plate: Q235B, Inside acid-resisting, alkali-resisting refractory poured material. With ash door and filtration material. [1 unit ] 1# BURNER OF 1# CHAMBER Riello brand (Italy) (High quality, combustion-resisting) Fuel: Natural gas [1 unit ] 2# BURNER OF 2# CHAMBER Riello brand (Italy) (High quality, combustion-resisting) Fuel: Natural gas [1 unit ] Chimney Material: Stainless steel,304 Length: 5m ( other length as customer request) [1 unit ] Temperature control device -Thermocouple...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/  Email: sales@clovermed.netEmail: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/  Email: sales@clovermed.netEmail: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd. HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection,...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/  Email: sales@clovermed.netEmail: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd. HICLOVER is now offering a full range of medical waste incinerators, designed to...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/  Email: sales@clovermed.netEmail: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS30(PLC) Picture   Burn Rate Average 30-50 kg/hour Feed Capacity Average 60kg/feeding Control...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/  Email: sales@clovermed.netEmail: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd. Incinerator Model TS10 PLC, Overview   This model Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 100Liters (0.1m3, TS10 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation....
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/  Email: sales@clovermed.netEmail: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd. Model YD-30  Burning Rate  average 30 kgs/hour Feed Capacity average 40 kgs Paimary...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/  Email: sales@clovermed.netEmail: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd. ● Double Combustion Chambers All waste incinerator design with double combustion chamber. High...