biohazard waste disposal guidelines 1. The ground should be flat when install the incinerator. There should be 100cm at least between the incinerator and the walls on the two sides and the back, which is in convenient maintenance and repair. 2. A), Place the incinerator main body(combustion chamber) and fixed with bolts and Asbestos tape. B), Place the wet scrubber system and fixed with bolts and Asbestos tape. C). Install chimneys and fixed with bolts, Asbestos tape and Steel Rope. D). Fix the incineration house roof. E). Fix burner, blower, wind tube, electric system, fuel system. 3. Check the electric wire: the incinerator’s electric circuit should be linked with the ground wire to guard against current leakage. The link-up of the electric wire should be checked carefully before starting the incinerator, in case of wrong link-up or leakage. 4. Check of the fuel supply system: Except the Burner’s soft pipe which is used for the fuel flowing-in and flowing-back, all the rest pipes must use brass or steel pipe. No leakage is allowed at pipe junctions. Any leakage should be blocked in time. 5. Install steel rope with the chimney, to avoid tilt by wind. 6. Install net cover at the blower, to avoid sundries. 7. If the fuel is Natural Gas with gas burner, please contact with local administration section and install gas supplier system. 8. Crane or forklift is necessary when download/upload/install incinerator. 9. Topped work house roof after installation. 10.Get the video material: http://www.eclover.net/category/incinerator-video/...
Medical Environmental
diesel powered incinerator means the burner type is light oil with diesel oil fuel. the incinerator made by us...
we supply incinerator for Kenya, with IDF SGS certification. the HS code of incinerator is 84178050. if...
small scale municipal solid waste inceneration technologies including key point is high temerature combustion. the chamber made with heavy duty refractory material, we...
How medical waste is incinerated? The pyrolytic incinerator comprises a pyrolytic chamber and a post-combustion chamber. Medical waste is thermally decomposed in the pyrolytic chamber through an oxygen-deficient, medium-temperature combustion process (800– 900°C), producing solid ashes and gases. What are the treatment methods for treatment of bio medical waste? Thermal processes Low-heat systems (operates between 93 -177oC) use steam, hot water, or electromagnetic radiation to heat and decontaminate the waste High-heat systems employ combustion and high temperature plasma to decontaminate and destroy the waste. … Incineration. Autoclaving. Microwaving. Deep Burial. Nanjing Clover Medical Technology...
we produce incinerator for the waste incinerator for covid19 ppe waste, small capacity is 5-10kgs per hour powered by diesel oil. high...
we supply brand new incinerator for animal waste incinerator for farm,pig,chicken, Agriculture, farms, pigs, cattle, sheep, chickens,...
how does the incinerator works? the incinerator mainly for medical waste and animal waste treatment with oil/gas fired in the primary...
what’s the incinerator of hospital pictures and drawings? if you want to build or buy new incinerator for hospital, confirm the waste...
we use latest incinerator technology with high temperature combustion with 2 or 3 chambers, with wet scrubber or dry...
we supply medical two chambers incinerator 800 to 1200 degrees. the capacity from 10kgs per hour to moran than 1000kgs per hour. all incinerator...
we supply kinds of spare parts for waste incinerator and oil or gas burners. SENSOR. BTL20/BTL26 BURNER, FLAME DETECTOR, QRB1B L=350 CAPTEUR. BTL20 / BTL26 BRULEUR, DETECTEUR DE FLAMME Motor...
TS10 PLC Waste Incinerator Outline Dimension:1.75 x 1.3 x 1.7m Weight: Ave.1500kgs Main body(Primary combustion chamber) Material:Carbon Steel Q235B+Stainless Steel 310s+refractory firebrick material(high temperature resistance up to 1750℃) Capacity: 10-20kg/batch Combustion temperature: 800-1000℃ With chamber door, oxygen supplementation wind port, burner port, temperature control and alarm device, etc. [1 unit ] Secondary combustion chamber Material:Carbon Steel Q235B+Stainless Steel 310s+refractory firebrick material(high temperature resistance up to 1750℃) Combustion temperature:1000-1200℃ With observation port, burner port, temperature control and alarm device, etc. [1 unit ] High temperature flue gas filtration chamber Material: Outside plate: Q235B, Inside acid-resisting, alkali-resisting refractory poured material. With ash door and filtration material. [1 unit ] 1# BURNER OF 1# CHAMBER Riello brand (Italy) (High quality, combustion-resisting) Fuel: Natural gas [1 unit ] 2# BURNER OF 2# CHAMBER Riello brand (Italy) (High quality, combustion-resisting) Fuel: Natural gas [1 unit ] Chimney Material: Stainless steel,304 Length: 5m ( other length as customer request) [1 unit ] Temperature control device -Thermocouple...
pictures of 500kg per hour machine Items/Model TS500(PLC) Picture Principle Medical Waste Incineration Treatment how many burners does the primary have...
incinerator for poultry farm dead checkin 575 kg, HICLOVER YD50 incinerator or TS50 Model YD-50 Picture Burning Rate Average 50 kgs/hour Feed...
there was one set oil fired incinerator send to Kenya. average capacity 30-50kgs per hour for small...
HICLOVER incinerator exert the advantages and discard the disadvantages of the same kind of equipment at domestic and...
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast...
Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local ...
Medical Waste Incinerator for Coronavirus Disease( COVID-19). * Full variety incinerator with Standard Small-Large Scale incinerator,...
HICLOVER Incinerator/Parts Range Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for...
Model A1500 Picture Brand/Product Code HICLOVER/N1134 Burning Rate Average 50 kgs/hour Feed Capacity Average 150 kgs/feeding...
Items/Model HICLOVER TS150(PLC) (Mobile Type) N1155 Picture mobile incinerator Principle Waste Incineration Treatment,trash incinerator Burn Rate Average 150 kg/hour Feed...
Items/Model TS50(PLC) Picture Principle Medical Waste Incineration,dual chamber incinerator Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller...
Items/Model TS50(PLC) Picture Principle Medical Waste Incineration Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion...
Items/Model TS500(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 500 kg/hour Control Mode PLC(Programmable Logic Controller...
Item Specification Model YD-20C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/ Email: sales@clovermed.netEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. 1. Incinerator 10kg per hr 2. Incinerator 20kg per hr 3. Incinerator 50kg per hr 4. Incinerator...
Items/Model TS800 Picture Principle Animal Waste Incineration Treatment Burn Rate Average 300-450 kg/hour Feed Capacity Average 1200kg/feeding Control...
Item Specification Model A1500 Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes...
Item Specification Model YD-20C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/ Email: sales@clovermed.netEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Equipment Technical Specifications Model TS30S Picture Feed Capacity 78 Liters for primary...
Items/Model TS75 Picture Principle Solid Waste Incineration Burn Rate Average 75 kg/hour Feed Capacity Average 100kg Control Mode...
The Incinerator units shall be designed to last in operation in a tropical environment for a minimum...
Waste Disposal Methods in Hospital • An 8 hour daily operating cycle of ash removal, pre-heat and...
Model A1500(Movable platform & Auto. Door) Picture Burning Rate Average 50 kgs/hour Feed Capacity Average 150 kgs/feeding...
Items/Model TS1000 Picture Principle Waste Incineration Treatment Burn Rate Average 1000 kg/hour Feed Capacity Average 3000kg/feeding Control...
Medical Waste Incinerator Capacity: average 50-100 kgs per hour Items/Model TS50(PLC) Picture Principle Medical Waste Incineration Burn Rate...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/ Email: sales@clovermed.netEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three...
The equipment proposed shall be an incinerator specialised for Medical Wastes. Medical waste may consist of discarded...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/ Email: sales@clovermed.netEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/ Email: sales@clovermed.netEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection,...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/ Email: sales@clovermed.netEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. HICLOVER is now offering a full range of medical waste incinerators, designed to...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/ Email: sales@clovermed.netEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS30(PLC) Picture Burn Rate Average 30-50 kg/hour Feed Capacity Average 60kg/feeding Control...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/ Email: sales@clovermed.netEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Incinerator Model TS10 PLC, Overview This model Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 100Liters (0.1m3, TS10 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation....
Top Openning Door Waste Incinerators Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour...
HICLOVER Top Feeding Door Waste Incinerators ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section...
HICLOVER Top Feeding Door Waste Incinerators ***Primary Combustion Chamber ***Secondary Combustion Chamber ***Smoke Filter Chamber ***Optional Wet...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/ Email: sales@clovermed.netEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Model YD-30 Burning Rate average 30 kgs/hour Feed Capacity average 40 kgs Paimary...
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.clovermed.net/ Email: sales@clovermed.netEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. ● Double Combustion Chambers All waste incinerator design with double combustion chamber. High...